Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
4.
J Clin Med ; 12(23)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38068420

RESUMO

In current clinical practice, commissural alignment of the transcatheter heart valve (THV) during transcatheter aortic valve implantation (TAVI) is seldom achieved. Orientation of the THV within the aortic root and the subsequent influence upon leaflet haemodynamic function, coronary blood flow, and ease of access to the coronary ostia are gaining significant interest. Herein, we review the incidence and clinical implications of commissural misalignment in TAVI and offer thorough descriptions of how optimal alignment can be achieved with several different contemporary THV devices.

5.
J Clin Med ; 12(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38137816

RESUMO

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

8.
Diabetes Ther ; 14(11): 1853-1865, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37665429

RESUMO

INTRODUCTION: Sodium-glucose type 2 cotransporter inhibitors (SGLT2-I) have shown solid benefits in reducing cardiovascular mortality and admissions for heart failure in patients with type 2 diabetes mellitus (T2DM) and cardiovascular disease. However, no specific studies exist in patients with high-risk coronary artery disease (CAD). METHODS: Single-center, retrospective, observational study including patients with T2DM and a new diagnosis of extensive CAD (defined as left main disease or three main coronary vessel disease). Patients were recruited from 2015 until 2020, with a follow-up of at least 12 months. The primary outcome was to compare all-cause mortality in patients treated with or without SGLT2-I at discharge and adjusted by inverse probability of treatment weighting (IPTW) propensity score. RESULTS: A total of 420 patients were included: 104 (24.7%) were treated with SGLT2-I and 316 (75.3%) were not (non-SGLT2-I group). The presentation was acute coronary syndrome in 44.3%. The mean age was 71.2 ± 10.5 years. The mean left ventricular ejection fraction was 51.5 ± 12.5%, and the mean estimated glomerular filtration rate was 73.9 ± 22 ml/min. After a mean follow-up of 3 ± 1.6 years, all-cause mortality was 16.4%, and cardiovascular mortality was 9.5%. After IPTW, the risk of all-cause death was lower in the SGLT2-I group with a hazard ratio of 0.32 (95% confidence interval 0.12-0.81), p = 0.016. With regard to secondary outcomes, patients in the SGLT2-I group were associated with less renal function deterioration but an increase in unplanned revascularizations. CONCLUSIONS: In patients with T2DM and extensive CAD, treatment with SGLT2-I after discharge was associated with a reduced risk of all-cause death.

9.
JACC Cardiovasc Interv ; 16(17): 2153-2164, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37704301

RESUMO

BACKGROUND: In patients undergoing percutaneous coronary intervention (PCI) in the work-up pre-transcatheter aortic valve replacement (TAVR), the incidence and clinical impact of late bleeding events (LBEs) remain largely unknown. OBJECTIVES: This study sought to determine the incidence, clinical characteristics, associated factors, and outcomes of LBEs in patients undergoing PCI in the work-up pre-TAVR. METHODS: This was a multicenter study including 1,457 consecutive patients (mean age 81 ± 7 years; 41.5% women) who underwent TAVR and survived beyond 30 days. LBEs (>30 days post-TAVR) were defined according to the Valve Academic Research Consortium-2 criteria. RESULTS: LBEs occurred in 116 (7.9%) patients after a median follow-up of 23 (IQR: 12-40) months. Late bleeding was minor, major, and life-threatening or disabling in 21 (18.1%), 63 (54.3%), and 32 (27.6%) patients, respectively. Periprocedural (<30 days post-TAVR) major bleeding and the combination of antiplatelet and anticoagulation therapy at discharge were independent factors associated with LBEs (P ≤ 0.02 for all). LBEs conveyed an increased mortality risk at 4-year follow-up compared with no bleeding (43.9% vs 36.0; P = 0.034). Also, LBE was identified as an independent predictor of all-cause mortality after TAVR (HR: 1.39; 95% CI: 1.05-1.83; P = 0.020). CONCLUSIONS: In TAVR candidates with concomitant significant coronary artery disease requiring percutaneous treatment, LBEs after TAVR were frequent and associated with increased mortality. Combining antiplatelet and anticoagulation regimens and the occurrence of periprocedural bleeding determined an increased risk of LBEs. Preventive strategies should be pursued for preventing late bleeding after TAVR, and further studies are needed to provide more solid evidence on the most safe and effective antithrombotic regimen post-TAVR in this challenging group of patients.


Assuntos
Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Cateteres
10.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37758382

RESUMO

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
11.
Rev. esp. cardiol. (Ed. impr.) ; 76(8): 600-608, Agos. 2023. graf, ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-223493

RESUMO

Introducción y objetivos: La enfermedad coronaria (EC) es frecuente en pacientes con estenosis aórtica; sin embargo, la estrategia terapéutica óptima sigue siendo objeto de debate. Investigamos los resultados periprocedimiento en pacientes sometidos a implante percutáneo de válvula aórtica con intervención coronaria percutánea (TAVI/ICP) frente al recambio valvular aórtico con injerto de derivación de arteria coronaria (RVAo/CABG) en pacientes con estenosis aórtica con EC.Métodos: Con los datos de alta del Sistema Nacional de Salud Español, se identificaron 6.194 pacientes (5.217 RVAo/CABG y 977 TAVI/ICP) entre 2016 y 2019. Se realizó un análisis emparejado por puntuación de propensión ajustado por características basales. El objetivo primario fue la mortalidad hospitalaria, Los objetivos secundarios fueron las complicaciones hospitalarias y rehospitalización cardiovascular a 30 días.Resultados: Tras el emparejamiento, se seleccionaron 774 parejas de pacientes. La mortalidad total hospitalaria fue más frecuente en el grupo quirúrgico (3,4 frente a 9,4%, p <0,001), al igual que el ictus periprocedimiento (0,9 frente a 2,2%, p=0,004), fallo renal agudo (4,3 frente a 16,0%, p <0,002), transfusión (9,6 frente a 21,1%, p <0,001) y neumonía intrahospitalaria (0,1 frente a 1,7%, p=0,001). La implantación de marcapasos permanente fue más frecuente en el tratamiento percutáneo (12,0 frente a 5,7%, p <0,001). Los centros de menor volumen (< 130 procedimientos por año) tuvieron mayor mortalidad hospitalaria para ambos procedimientos: TAVI/ICP (3,6 frente a 2,9%, p <0,001) y RVAo/CABG (9,3 frente a 6,8%, p <0,001). La rehospitalización cardiovascular a 30 días no difirió entre los grupos.(AU)


Introduction and objectives: Concomitant coronary artery disease (CAD) is prevalent among aortic stenosis patients; however the optimal therapeutic strategy remains debated. We investigated periprocedural outcomes among patients undergoing transcatheter aortic valve implantation with percutaneous coronary intervention (TAVI/PCI) vs surgical aortic valve replacement with coronary artery bypass grafting (SAVR/CABG) for aortic stenosis with CAD.Methods: Using discharge data from the Spanish National Health System, we identified 6194 patients (5217 SAVR/CABG and 977 TAVI/PCI) between 2016 and 2019. Propensity score matching was adjusted for baseline characteristics. The primary outcome was in-hospital all-cause mortality. Secondary outcomes were in-hospital complications and 30-day cardiovascular readmission.Results: Matching resulted in 774 pairs. In-hospital all-cause mortality was more common in the SAVR/CABG group (3.4% vs 9.4%, P <.001) as was periprocedural stroke (0.9% vs 2.2%; P=.004), acute kidney injury (4.3% vs 16.0%, P <.001), blood transfusion (9.6% vs 21.1%, P <.001), and hospital-acquired pneumonia (0.1% vs 1.7%, P=.001). Permanent pacemaker implantation was higher for matched TAVI/PCI (12.0% vs 5.7%, P <.001). Lower volume centers (< 130 procedures/y) had higher in-hospital all-cause mortality for both procedures: TAVI/PCI (3.6% vs 2.9%, P <.001) and SAVR/CABG (8.3 vs 6.8%, P <.001). Thirty-day cardiovascular readmission did not differ between groups.Conclusions: In this large contemporary nationwide study, percutaneous management of aortic stenosis and CAD with TAVI/PCI had lower in-hospital mortality and morbidity than surgical intervention. Higher volume centers had less in-hospital mortality in both groups. Dedicated national high-volume heart centers warrant further investigation.(AU)


Assuntos
Humanos , Masculino , Feminino , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/terapia , Doença da Artéria Coronariana/cirurgia , Doenças Cardiovasculares , Espanha/epidemiologia , Doença da Artéria Coronariana/terapia , Análise por Pareamento , Mortalidade Hospitalar
12.
Rev. esp. cardiol. (Ed. impr.) ; 76(7): 503-510, jul. 2023. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-222320

RESUMO

Introducción y objetivos: La amiloidosis cardiaca por transtirretina (ACTTR) se asocia con fibrilación auricular y un riesgo trombótico y hemorrágico aumentados. Nuestro objetivo fue evaluar los resultados del cierre percutáneo de orejuela izquierda (COI) comparado con pacientes sin diagnóstico conocido de ACTTR. Métodos: Comparación de la evolución a largo plazo de pacientes con diagnóstico de ACTTR frente a pacientes sin ese diagnóstico sometidos a COI entre 2009 y 2021. Resultados: Se incluyó a 1.159 pacientes de los que 40 (3,5%) fueron diagnosticados de ACTTR; fueron más ancianos, con más comorbilidades, mayores puntuaciones HAS-BLED y CHA2DS2-VASc y menor función ventricular izquierda. Se consiguió el COI exitoso en 1.137 pacientes (98,1%) sin diferencias entre los grupos. No hubo diferencias intrahospitalarias ni al seguimiento en ictus isquémico (5 frente a 2,5%, p=0,283), ictus hemorrágico (2,5 frente a 0,8%, p=0,284), ni sangrado mayor o menor. La mortalidad a 2 años no presentaba diferencias entre los pacientes con ACTTR y los que no presentaban este diagnóstico (20 frente a 13,6%, 0,248); sin embargo, a los 5 años los pacientes ACTTR presentaron mayor mortalidad (40 frente a 19,2%, p <0,001) pero no relacionada con complicaciones hemorrágicas o ictus isquémico. Conclusiones: El COI podría reducir complicaciones hemorrágicas y accidentes cerebrovasculares sin incrementar las complicaciones precoces en pacientes con ACTTR. Aunque la supervivencia a largo plazo en pacientes con ACTTR es muy reducida, a dos años fue comparable a la del grupo sin diagnóstico de ACTTR lo que sugiere que el COI no es fútil en pacientes con ACTTR. (AU)


Introduction and objectives: Transthyretin cardiac amyloidosis (ATTR-CA) patients often have atrial fibrillation and increased bleeding/thrombogenic risks. We aimed to evaluate outcomes of left atrial appendage closure (LAAC) compared with patients without a known diagnosis of CA. Methods: Comparison at long-term of patients diagnosed with ATTR-CA who underwent LAAC between 2009 and 2020 and those without a known diagnosis of CA. Results: We studied a total of 1159 patients. Forty patients (3.5%) were diagnosed with ATTR-CA; these patients were older and had more comorbidities, higher HAS-BLED and CHA2DS2-VASc scores, and lower left ventricular function. Successful LAAC was achieved in 1137 patients (98.1%) with no differences between groups. Regarding in-hospital and follow-up complications, there were no differences between the groups in ischemic stroke (5% vs 2.5% in those without a known diagnosis of CA; P=.283), hemorrhagic stroke (2.5% and 0.8% in the control group; P=.284), major or minor bleeding. At the 2-year follow-up, there were no significant differences in mortality (ATTR-CA: 20% vs those without known CA: 13.6%, 0.248); however, the at 5-year follow-up, ATTR-CA patients had higher mortality (40% vs 19.2%; P <.001) but this difference was unrelated to hemorrhagic complications or ischemic stroke. Conclusions: LAAC could reduce the risk of bleeding complications and ischemic cerebrovascular events without increasing the rate of early or mid-term complications. Although long-term survival was impaired in ATTR-CA patients, it was comparable to that of patients without a known diagnosis of CA at the 2-year follow-up, suggesting that LAAC for patients with ATTR-CA might not be futile. (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Amiloidose , Cardiopatias , Espanha , Estudos Retrospectivos , Pré-Albumina , Acidente Vascular Cerebral , Insuficiência Cardíaca
13.
EuroIntervention ; 19(4): e340-e351, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37334654

RESUMO

BACKGROUND: A small aortic annulus (SAA) is a risk factor for prosthesis-patient mismatch (PPM) in patients undergoing surgical or transcatheter aortic valve implantation (TAVI). Data regarding TAVI in patients with extra-SAA are scarce. AIMS: The aim of this study was to analyse the safety and efficacy of TAVI in patients with extra-SAA. METHODS: A multicentre registry study including patients with extra-SAA (defined as an aortic annulus area <280 mm2 and/or perimeter <60 mm) undergoing TAVI was established. Primary efficacy and safety endpoints were defined as device success and early safety at 30 days, respectively, using the Valve Academic Research Consortium-3 criteria, and were analysed according to valve type: self-expanding (SEV) versus balloon-expandable (BEV). RESULTS: A total of 150 patients were included, of which 139 (92.7%) were women, and 110 (73.3%) received an SEV. Intraprocedural technical success was 91.3%, with a higher rate in patients receiving an SEV (96.4% vs 77.5% with BEV; p=0.001). Overall, 30-day device success was 81.3%, (85.5% with SEV vs 70.0% with BEV; p=0.032). The primary safety endpoint occurred in 72.0% of patients (with no difference between groups; p=0.118). Severe PPM occurred in 12% (9.0% with SEV and 24.0% with BEV; p=0.039), with no impact on all-cause mortality, cardiovascular mortality, or heart failure readmission at 2-year follow-up. CONCLUSIONS: TAVI is a safe and feasible treatment in patients with extra-SAA with a high rate of technical success. The use of SEV was associated with a lower rate of intraprocedural complications, higher device success at 30 days and better haemodynamic outcomes compared to BEV.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
14.
Front Cardiovasc Med ; 10: 1195397, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37229228

RESUMO

Encouraged by randomized controlled trials demonstrating non-inferiority of transfemoral transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) across all surgical risk categories, there has been a dramatic increase in the use of TAVI in a younger patient cohort with severe aortic stenosis, endorsed by both European and American Cardiac Societies. However, the standard use of TAVI in younger, less co-morbid patients with a longer life expectancy can only be supported if there is sound data demonstrating long-term durability of transcatheter aortic valves (TAVs). In this article, we have reviewed available randomized and observational registry clinical data pertaining to TAV long-term durability, placing emphasis on trials and registries using the new standardized definitions of bioprosthetic valve dysfunction (BVD) and bioprosthetic valve failure (BVF). Despite inherent difficulties in interpreting the available data, the determination reached is that the risk of structural valve deterioration (SVD) is potentially lower after TAVI than SAVR at 5 to 10 years, and that the two treatment modalities have a similar risk of BVF. This supports the adoption of TAVI in younger patients evident in current practice. However, the routine use of TAVI in younger patients with bicuspid aortic valve stenosis should be cautioned due to insufficient long-term TAV durability data in this particular patient population. Finally, we highlight the importance of future research into the unique potential mechanisms that can potentially contribute to TAV degeneration.

15.
Heart ; 109(18): 1401-1406, 2023 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-37217297

RESUMO

INTRODUCTION: Estimation of peri-procedural risk in patients with tricuspid regurgitation (TR) undergoing isolated tricuspid valve surgery (ITVS) is of paramount importance. The TRI-SCORE is a new surgical risk scale specifically developed for this purpose, which ranged from 0 to 12 points and included eight parameters: right-sided heart failure signs, daily dose of furosemide ≥125 mg, glomerular filtration rate <30 mL/min, elevated bilirubin (with a value of 2 points), age ≥70 years, New York Heart Association Class III-IV, left ventricular ejection fraction <60% and moderate/severe right ventricular dysfunction (with a value of 1 point). The objective of the study was to evaluate the performance of the TRI-SCORE in an independent cohort of patients undergoing ITVS. METHODS: A retrospective observational study was performed in four centres, including consecutive adult patients undergoing ITVS for TR between 2005 and 2022. The TRI-SCORE and the traditional risk scores used in cardiac surgery (Logistic EuroScore (Log-ES) and EuroScore-II (ES-II)) were applied for each patient, and discrimination and calibration of the three scores were evaluated in the entire cohort. RESULTS: A total of 252 patients were included. The mean age was 61.5±11.2 years, 164 (65.1%) patients were female, and TR mechanism was functional in 160 (63.5%) patients. The observed in-hospital mortality was 10.3%. The estimated mortality by the Log-ES, ES-II and TRI-SCORE was 8.7±7.3%, 4.7±5.3% and 11.0±16.6%, respectively. Patients with a TRI-SCORE ≤4 and >4 had an in-hospital mortality of 1.3% and 25.0%, p=0.001, respectively. The discriminatory capacity of the TRI-SCORE had a C-statistic of 0.87 (0.81-0.92), which was significantly higher than both the Log-ES (0.65 (0.54-0.75)) and ES-II (0.67 (0.58-0.79)), p=0.001 (for both comparisons). CONCLUSION: This external validation of the TRI-SCORE demonstrated good performance to predict in-hospital mortality in patients undergoing ITVS, which was significantly better than the Log-ES and ES-II, which underestimated the observed mortality. These results support the widespread use of this score as a clinical tool.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Volume Sistólico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Fatores de Risco , Estudos Retrospectivos
16.
Circ Cardiovasc Interv ; 16(3): e012554, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36943930

RESUMO

BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese
17.
Cardiovasc Revasc Med ; 52: 59-66, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36878760

RESUMO

BACKGROUND: Intracoronary lithotripsy (IVL) is a safe and effective treatment for coronary calcification. Angiographic and intracoronary imaging follow-up have not yet been described. We aimed to describe the mid-term angiographic outcomes following IVL. METHODS: Patients successfully treated with IVL in two tertiary referral hospitals were included. Repeat angiography and intracoronary imaging was performed. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) analyses were performed using dedicated workstations. RESULTS: Twenty patients were included; mean age 67.1 years, left anterior descending artery 55 %. Median IVL balloon size was 3.0 mm and a median of 60 pulses were delivered per vessel. Percentage stenosis by QCA was 60 % [IQR 51-70] reducing to 20 % post stenting (p < 0.001). On OCT, 88.9 % had circumferential calcium. IVL resulted in fractures in 88.9 %. Resulting minimum stent expansion was 91.75 % [IQR 81.5-108]. Follow-up was at a median of 22.7 months [IQR16.4-25.5]. Percentage stenosis by QCA was 22.5 % [IQR 14-30] and not significantly different from the index procedure (p > 0.05). Minimum stent expansion by OCT was 85 % [IQR 72-97]. Late luminal loss was 0.15 mm [IQR -0.25 to 0.69]. Binary angiographic instent restenosis (ISR) was 10 % (2 of 20 patients). OCT demonstrated a predominantly homogenous neointimal pattern with high backscatter. CONCLUSION: Following successful IVL treatment, repeat angiography demonstrated preserved stent parameters in the majority of patients with favorable vascular healing properties by OCT. A binary restenosis rate of 10 % was observed. These results suggest durable results following IVL treatment of severe coronary calcification however larger studies are warranted.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Litotripsia , Calcificação Vascular , Humanos , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Centros de Atenção Terciária , Angioplastia Coronária com Balão/efeitos adversos , Constrição Patológica , Angiografia Coronária/métodos , Resultado do Tratamento , Stents , Litotripsia/efeitos adversos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Calcificação Vascular/etiologia
19.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36804557

RESUMO

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
20.
Rev Esp Cardiol (Engl Ed) ; 76(8): 600-608, 2023 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36669732

RESUMO

INTRODUCTION AND OBJECTIVES: Concomitant coronary artery disease (CAD) is prevalent among aortic stenosis patients; however the optimal therapeutic strategy remains debated. We investigated periprocedural outcomes among patients undergoing transcatheter aortic valve implantation with percutaneous coronary intervention (TAVI/PCI) vs surgical aortic valve replacement with coronary artery bypass grafting (SAVR/CABG) for aortic stenosis with CAD. METHODS: Using discharge data from the Spanish National Health System, we identified 6194 patients (5217 SAVR/CABG and 977 TAVI/PCI) between 2016 and 2019. Propensity score matching was adjusted for baseline characteristics. The primary outcome was in-hospital all-cause mortality. Secondary outcomes were in-hospital complications and 30-day cardiovascular readmission. RESULTS: Matching resulted in 774 pairs. In-hospital all-cause mortality was more common in the SAVR/CABG group (3.4% vs 9.4%, P <.001) as was periprocedural stroke (0.9% vs 2.2%; P=.004), acute kidney injury (4.3% vs 16.0%, P <.001), blood transfusion (9.6% vs 21.1%, P <.001), and hospital-acquired pneumonia (0.1% vs 1.7%, P=.001). Permanent pacemaker implantation was higher for matched TAVI/PCI (12.0% vs 5.7%, P <.001). Lower volume centers (< 130 procedures/y) had higher in-hospital all-cause mortality for both procedures: TAVI/PCI (3.6% vs 2.9%, P <.001) and SAVR/CABG (8.3 vs 6.8%, P <.001). Thirty-day cardiovascular readmission did not differ between groups. CONCLUSIONS: In this large contemporary nationwide study, percutaneous management of aortic stenosis and CAD with TAVI/PCI had lower in-hospital mortality and morbidity than surgical intervention. Higher volume centers had less in-hospital mortality in both groups. Dedicated national high-volume heart centers warrant further investigation.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...